| Sensor Element: |
|
Type K (NiCr-Ni) |
| |
|
Type J (Fe-CuNi) |
| |
|
Type E (NiCr-CuNi) |
| |
|
Type N (NiCrSi-NiSi) |
| |
|
Type T (Cu-CuNi) |
| |
|
|
| Temperature range: |
|
-328°F to +2300°F (depending upon element) |
| |
|
|
| Number of sensors: |
|
2-wire single circuit |
| |
|
4-wire dual circuit |
| |
|
|
| Classification tolerance: |
|
Class 2 and Class 1 per DIN EN 60584 |
| |
|
ISA standard and special to ANSI MC96.1-1982 |
| |
|
|
| Measuring point: |
|
Ungrounded or grounded |
| |
|
|
| Electrical approvals: |
|
CSA, FM, ATEX/IEC, NAMUR |
| |
|
|
| Options: |
|
Lengths and diameters standard or customer specific |
| |
|
Transmitter mounted directly within connection head or on measuring insert DIN plate |
| |
|
Calibration - single point and multiple points |
| |
|
Material traceability of the thermocouple alloys, metal sheath and mineral insulation |
| |
|
Selectable accuracy tolerance |
| |
|
Exchangeable measuring insert |
| |
|
Special designs and materials |
| |
|
Explosion protection: CSA, FM, ATEX (EEx-d) |
| |
|
Intrinsically safe version: ATEX (EEx-i) |
| |
|
Non-sparking version: ATEX (EEx-n) |
| |
|
Thermocouple transmitter matching |