Type 711.12, Copper Alloy Wetted Parts, Type 731.12, Stainless Steel Wetted Parts
Applications
DesignTwo independent measuring systems, parallel in-line pressure entry
Sizes4" & 6" (100 mm & 160 mm)
Accuracy+ 1.5% of full scale value
RangesPressure from 10 psi (0.6 bar) to 15,000 psi (1,000 bar)Scale range must be selected based on the highest working pressure applied. The pressure differential to be indicated should be no less than 1/6 of the full scale range. When ordering please state both the max working pressure applied and the differential to be indicated.
Working RangeSteady: full scale valueFluctuating: 0.9 x of full scale valueShort time: 1.3 x full scale value
Operating TemperatureAmbient: -4°F to 140°F (-20°C to 60°C) 1,000 psi (70 bar)Media: max. 140°F (+60°C) max. 212oF (+100oC) - 1,000 psi (70 bar)
Temperature ErrorAdditional error when temperature changes from reference temperature of 68°F (20°C) +0.4% of span for every 18°F (10°K) rising or falling.
Weather ProtectionWeather resistant (NEMA 2 / IP 33)
ConnectionMaterial: copper alloyLower mount (LM) only2 x 1/4" or 1/2" NPTEach side marked with ⊕ or ⊖
Bourdon Tube≤ 1,000 psi (70 bar): C-shape,> 1,000 psi (70 bar): Helical stainless steel
MovementBrass
DialWhite aluminum with black lettering
PointerMaterial: aluminum1 black non-adjustable pointer1 graduated disc indicator with red tip and ± 50%of primary scale range
CaseBlack painted steel
WindowInstrument glass
Cover RingBlack painted steel screw retained
Operating PrincipleThe right connector (marked "+") indicates the high pressure side and operates the moving disc with red tip. The left connector (marked "-") indicates the low pressure side and operates the black pointer.
Model 904
For use with inductive contact devices
Model 910.14
For pressure measuring instruments
Model 905
For magnetic snap-action contacts
Model 910.16
Model 910.17
For measuring instruments and instrumentation accessories
Models 732.18, 733.18
For refrigeration technology, stainless steel, NS 80 and 100